Q

How does the range hood work?

A

According to the basic principles of fluid mechanics, the motor drives the wind wheel to rotate. In the air inlet and air cabinet, the air outlet generates a negative pressure, and the pressure difference between the air outlet, the air cabinet and the air outlet is realized, which leads to the suction and discharge of air. The oil fume is sucked and discharged due to the pressure difference. When the oil fume passes through the air inlet filter screen, part of the oil fume is cooled and separated, and the cooled and condensed slop is introduced into the oil cup and discharged from the body along the oil guide system, while the rest of the slop is discharged It will be produced by agglomeration in the internal cavity of the machine, and will be discharged from the machine body along the oil guiding system, and the fumes after oil fume separation will be discharged from the air outlet.

Q

What is the basic working principle of the stove?

A

The basic working principle can be divided into ignition phase, primary mixed combustion, ignition phase and combustion phase. Ignition stage: Open the valve during ignition, the gas enters through the pipeline with a certain pressure and is ejected from the nozzle; primary mixed combustion: due to the ejection effect of the kinetic energy of the gas, the gas ejected from the nozzle draws in the primary air from the air door and is in the ejector. The ignition phase of the mixed gas is completed inside: the mixed gas flows out through the fire hole of the burner and starts to ignite when it encounters the fire source generated by the igniter; the combustion process: after ignition, the gas obtains secondary air supplement from the burner and completes the complete combustion.

Q

Disinfection cabinet news answer

A

How the product works

  Disinfection of tableware is a process of using physical or chemical methods to kill pathogenic microorganisms in cleaned tableware. In terms of function, disinfection cabinets on the market usually have three disinfection methods: high temperature disinfection, ozone disinfection and ultraviolet disinfection, as well as the combined disinfection methods between them. The following is a brief description of its working principle.

Electric tableware disinfection cabinet

  The electric heating disinfection cabinet for tableware is a disinfection cabinet which is heated by electric heating elements to disinfect the tableware. The high temperature disinfection cabinet is the most common electric heating disinfection cabinet on the market. It uses high temperature to play a bactericidal effect. In the high temperature and dry air, it has an obvious lethal effect on bacteria. The protein in bacteria and viruses is denatured and solidified due to heat, the activity disappears, and the metabolism is blocked, leading to death. Usually, milky white quartz heating tube is used for heating. In the form of far-infrared direct radiation and air convection, the items and air in the cabinet are heated to above the set temperature, and the high temperature must be maintained for longer than the specified time.

  In order to reach the set disinfection temperature and time, the high-temperature disinfection cabinet adopts a thermostat or a microcomputer program to control the working time of the disinfection cabinet, and the power is automatically cut off when the work is completed.

Ozone disinfection cabinet

  The electric heating disinfection cabinet for tableware is a disinfection cabinet which is heated by electric heating elements to disinfect the tableware. The high temperature disinfection cabinet is the most common electric heating disinfection cabinet on the market. It uses high temperature to play a bactericidal effect. In the high temperature and dry air, it has an obvious lethal effect on bacteria. The protein in bacteria and viruses is denatured and solidified due to heat, the activity disappears, and the metabolism is blocked, leading to death. Usually, milky white quartz heating tube is used for heating. In the form of far-infrared direct radiation and air convection, the items and air in the cabinet are heated to above the set temperature, and the high temperature must be maintained for longer than the specified time.

  In order to reach the set disinfection temperature and time, the high-temperature disinfection cabinet adopts a thermostat or a microcomputer program to control the working time of the disinfection cabinet, and the power is automatically cut off when the work is completed.

UV disinfection cabinet

  The principle of ultraviolet sterilization is to use ultraviolet light with a central wavelength of 253.7nm from an ultraviolet lamp to directly irradiate bacteria, viruses and microorganisms with a certain irradiation intensity and irradiation time to destroy their tissues and die. The penetration ability of ultraviolet light is very weak, and the backlight part of the object cannot be disinfected. Therefore, the national standard clearly stipulates that the disinfection cabinet that only depends on ultraviolet disinfection cannot be used for disinfection of tableware. The high-ozone ultraviolet lamp made of special quartz glass produces sterilized 253.7nm ultraviolet rays while also producing 184.9nm ultraviolet rays at the center wavelength. The 184.9nm ultraviolet rays can synthesize oxygen molecules in the air into ozone molecules. Therefore, the high-ozone ultraviolet lamp can be used as the disinfection source of the tableware disinfection cabinet. Ultraviolet rays + ozone + medium temperature is the most popular disinfection method for UV tableware disinfection cabinets on the market.

  Ultraviolet rays have a strong irritation to human skin and cornea. Looking directly at the UV lamp for a few minutes can cause eye pain, redness and swelling. Quartz glass can pass ultraviolet rays well, while ordinary glass is basically opaque. Therefore, the ultraviolet disinfection cabinet must be equipped with a door switch to prevent human radiation damage from ultraviolet rays.


Common fault repair principle

Fault name

Failure phenomenon

Cause Analysis

Troubleshooting method

The whole machine does not work, leakage

The whole machine does not work

No electricity or poor contact in the power socket 

Use a multimeter to check if there is electricity or change the socket 

Blown fuse 

Replace the fuse of the same specification 

Poor contact or open circuit between the power cord and the circuit board 

Check whether the power cord socket is connected to the circuit board and repair it

Circuit board failure

Replace the circuit board

Automatic alarm

The door switch is not closed

Adjust the baffle of the door control part or replace the door control switch

Leakage

The support leg of the circuit board is broken and touches the shell 

Reinstall the bracket or separate with insulating material

There are foreign objects around the circuit board and switch display that are connected to the shell 

Clean up foreign objects around the circuit board and switch display

The wire insulation layer is aging, damaged and touches the shell

Replace wire or repair

Poor drying and high temperature effect

Poor drying and high temperature effect

Too much tableware is stacked in the cabinet, too dense

Adjust the number and spacing

The cabinet door is not closed tightly, and the door seal is deformed and heat overflows

Adjust the fixing screw of the door hinge seat or replace the door seal

One of the quartz heating tubes burned out

Replace the quartz tube

The conductive column of the heating tube is loose and the contact is poor

Re-tighten

The temperature limit of the thermostat is too low

Replace the thermostat

The resistance wire of the heating tube becomes thinner, the resistance increases and the power decreases

Observe the brightness of the heat and the color of the heat pipe after the power is off and replace it


Fault name

Failure phenomenon

Cause Analysis

Troubleshooting method

UV lamp does not work

UV lamp does not work

Transport is too savage,Cause the lamp tube contact and the lamp holder contact to shift.

Just turn the UV lamp

Check whether the connecting wire is off or broken, causing the whole circuit to be blocked

After the entire line is transmitted, check whether the entire circuit is unblocked with a multimeter, and pay special attention to whether the UV lamp socket is in poor contact
Check if the rectifier has voltage output

Replace the electronic ballast of the same specification

Visually check whether the tungsten filament of the UV lamp is disconnected

Replace the lamp with the same specification

   Ozone does not produce Ozone does not produce Check whether the cabinet door is closed well, and confirm whether it is caused by the door control switch not being closed Close the cabinet door or adjust the cabinet door, or press it by hand to confirm whether it is effective
Whether the gate control switch is on and off normally, judge whether the gate control switch is in bad contact Use a multimeter to check whether the contact performance of the door control switch meets the requirements
Check whether the connecting wire is off or broken, causing the whole circuit to be blocked After the entire line is transmitted, use a multimeter to check whether the entire loop is unblocked
The power supply of the ozone generator is abnormal

Use a multimeter to measure whether there is voltage output at the output of the ozone generator on the main control circuit board, and the circuit board is not replaced.

No ozone Replace electronic ballast
The tableware is yellow or there is peculiar smell or mold in the cabinet Tableware turns yellow The tableware is dirty, and the inside of the cabinet with organic storage is dirty

Keep the tableware clean and the cabinet clean

The temperature limit of the disinfection thermostat is too high

Replace the thermostat with the same specification

Smell The cabinet door was opened before the ozone was decomposed

The door can only be opened after 20 minutes of power failure

Get mouldy The tableware was placed in the disinfection cabinet and the disinfection program was not started in time

Communicate with customers and start the disinfection program in time

Precautions for daily maintenance and use of disinfection cabinet

} Precautions for daily cleaning and maintenance

1、The power plug must be unplugged when cleaning the disinfection cabinet;

2、Wipe the inner and outer surfaces of the cabinet with a warm and damp cloth, wipe with a neutral detergent, and then wipe with a clean cloth;

3、Avoid cleaning with hot water, gasoline, alcohol, washing powder, and alkaline detergent. It is strictly forbidden to spray the cabinet with water directly to prevent the electrical insulation performance from degrading and causing danger.

4、It is strictly forbidden to directly splash water and spray the inner and outer boxes to avoid the risk of electric shock due to poor circuit insulation

} Precautions for daily use

1534814255235098329.jpg

1、The power socket of the disinfection cabinet must be installed with a reliable grounding wire, and the socket of the specified specification shall be used. The user shall not modify the plug without authorization, and it is strictly forbidden to operate without grounding; 

2、When the high temperature disinfection function is selected, it is only suitable for the disinfection of glass, ceramic, stainless steel and other tableware with a temperature of 170℃ or higher (except for the sealed cavity). It is forbidden to put low-temperature-resistant wooden and plastic tableware into a high-temperature box for disinfection, so as to avoid the danger of deformation, damage or burning, and not to put non-tableware (such as clothing, towels, shoes and hats, etc.) into the disinfection cabinet. Tableware whose temperature resistance is lower than 70℃ shall not be put into the disinfection cabinet;

3、Pour the water on the tableware to achieve a good disinfection effect. Too much water will cause circuit failure. The oil on the tableware should be thoroughly cleaned, otherwise the oil will cause peculiar smell in the cabinet, and there should be left between the tableware. In the gap, the tableware is crowded together, which will affect the disinfection effect;

4、After the cabinet door is closed, the disinfection cabinet can work normally. Please do not open the cabinet door during the disinfection process, otherwise it will affect the disinfection effect, prolong the disinfection time, and may even cause ozone leakage or ultraviolet radiation; the tableware should be washed and drained Then put it into the disinfection cupboard for disinfection, which can shorten the disinfection time and reduce the power consumption.

5、Hands and utensils should not touch the radiant panel to avoid being scalded and damaging the parts.  

6、If a large amount of ozone leakage is found during use or the light emitted by the ultraviolet lamp can be directly seen without passing through any light-transmitting objects, you should stop using it immediately, unplug the power plug, and notify the authorized maintenance outlet to perform repairs. Do not repair by yourself; 

7、After disinfection, the effect will be better if you take it out after 10 minutes. A small amount of ozone odor overflows when the cabinet door is opened. This concentration is not harmful to human health, please rest assured.

Previous page
1

Service Hotline:
400-930-0138

Address: Wentian Industrial Zone, Dongsheng Town, Zhongshan City, Guangdong Province
Join Hotline:18676416899(Manager Deng)

FAX:0760-22222707
E-mail: zschuzhibao@163.com

Copyright©Zhongshan Kitchen Utensils Treasure Electronics Co., Ltd

粤ICP备2021098952号 Powered by www.300.cn

Zhongshan Kitchen Utensils Treasure Electronics Co., Ltd. Reserves the right of final interpretation of any content displayed on this website